Technical Summary
| Product designation | SIMOTICS S Synchronous motor 1FK7-HD |
|---|---|
| Product lifecycle | Active Product |
| Rated power | PN=2.4kW |
| DC link voltage | UDC=600V |
| Static torque (100 K) | 12.00 Nm |
| Rated speed (100 K) | 4,500 rpm |
| Degree of protection | IP65 |
| Cooling | Natural cooling |
| Connector size | M23 |
| Electrical connectors | Connectors for signals and power rotatable |
| Encoder system | Resolver R15DQ: resolver 15 bits (resolution 32768, internal multi-pole) |
| Holding brake | with holding brake |
Applications
Motor for motion-control rotary drive output in SINAMICS S120 applications.
Supports holding the shaft with the built-in holding brake.
Key Features
SIMOTICS S synchronous motor, 1FK7-HD, for exact order-number identification.
PN=2.4kW; UDC=600V; M0=12Nm (100K); NN=4500rpm.
Naturally cooled, FRAME SIZE IMB 5 (IM V1, IM V3), flange 1.
Power connector rotatable; resolver multi-pole with DRIVE-CLiQ interface.
Plain shaft, tolerance N, with holding brake, Degree of protection IP65.
Frequently Asked Questions
What is Siemens 1FK7064-4CH71-1UH1?
It is a SIMOTICS S synchronous motor, 1FK7-HD, with Active Product lifecycle.
What are the key ratings of 1FK7064-4CH71-1UH1?
PN=2.4kW; UDC=600V; M0=12Nm (100K); NN=4500rpm.
Which interfaces and connectors are on 1FK7064-4CH71-1UH1?
It has a rotatable power connector, M23 connectors for signals and power, and a resolver multi-pole with DRIVE-CLiQ interface.
What protection and cooling does 1FK7064-4CH71-1UH1 have?
Degree of protection: IP65. Cooling: Natural cooling.
Does 1FK7064-4CH71-1UH1 include a holding brake and mounting design?
Yes. It is supplied with holding brake and Design acc. to Code I: IM B5 (IM V1, IM V3).