Technical Summary
| Product designation | SIMOTICS S Synchronous motor 1FK7 |
|---|---|
| PN | 0.63kW |
| UDC | 600V |
| M0 | 1.6Nm (100K) |
| NN | 6000rpm |
| Cooling | Naturally cooled |
| Mounting | FRAME SIZE IMB 5 (IM V1, IM V3) |
| Flange | FLANGE 1 |
| Temperature sensor | with KTY TEMPERATURESENSOR |
| Power connector | POWER CONNECTOR ROTATABLE |
| Feedback system | RESOLVER 2-POLE (RESOLVER P=1) |
| Protection | Degree of protection IP65 DE flange IP67 |
Applications
Servomotor use in SINAMICS S120 drive systems.
Key Features
Product designation: SIMOTICS S Synchronous motor 1FK7.
PN=0.63kW; M0=1.6Nm (100K).
UDC=600V; NN=6000rpm.
Naturally cooled; FRAME SIZE IMB 5 (IM V1, IM V3).
POWER CONNECTOR ROTATABLE; RESOLVER 2-POLE (RESOLVER P=1).
Degree of protection IP65 DE flange IP67; plain shaft, tolerance N; with holding brake.
Frequently Asked Questions
What is Siemens 1FK7034-2AK71-1TH2?
It is a SIMOTICS S synchronous motor / 1FK7 servomotor for SINAMICS S120.
What are the main electrical ratings of 1FK7034-2AK71-1TH2?
PN=0.63kW; UDC=600V; M0=1.6Nm (100K); NN=6000rpm.
What connector and feedback details are listed for 1FK7034-2AK71-1TH2?
It has a POWER CONNECTOR ROTATABLE and a RESOLVER 2-POLE (RESOLVER P=1).
What mounting, shaft, and protection details are listed for 1FK7034-2AK71-1TH2?
It is naturally cooled, uses FRAME SIZE IMB 5 (IM V1, IM V3), has FLANGE 1, a plain shaft with tolerance N, and degree of protection IP65 DE flange IP67.
What lifecycle status is listed for 1FK7034-2AK71-1TH2?
Product cancellation.