Technical Summary
| Product designation | SIMOTICS S Synchronous motor 1FK7-CT |
|---|---|
| PN | 0.59kW |
| UDC | 600V |
| M0 | 3Nm (100K) |
| NN | 2000rpm |
| Cooling | Naturally cooled |
| Frame size | FRAME SIZE IMB 5 (IM V1, IM V3) |
| Mounting | FLANGE 1 |
| Encoder | Absolute encoder 32 S/R SINGLETURN, 4096 ROTATION MULTITURN |
| Encoder interface | ENDAT- INTERFACE (ENCODER AM32S/R) |
| Shaft | plain shaft, tolerance N |
| Protection | Degree of protection IP65 DE flange IP67 |
| Brake | with holding brake |
| Lifecycle | Product cancellation |
Applications
Servo motor use in SINAMICS S120 systems.
Key Features
SIMOTICS S synchronous motor 1FK7-CT for SINAMICS S120.
PN=0.59kW; UDC=600V; M0=3Nm (100K); NN=2000rpm.
Naturally cooled, FRAME SIZE IMB 5 (IM V1, IM V3), FLANGE 1.
Absolute encoder 32 S/R SINGLETURN, 4096 ROTATION MULTITURN, with ENDAT- INTERFACE (ENCODER AM32S/R).
Plain shaft, tolerance N; with holding brake; degree of protection IP65 DE flange IP67.
Product cancellation.
Frequently Asked Questions
What is Siemens 1FK7042-2AC71-1GH2?
It is a SIMOTICS S synchronous motor 1FK7-CT.
What are the main ratings of 1FK7042-2AC71-1GH2?
PN=0.59kW, UDC=600V, M0=3Nm (100K), and NN=2000rpm.
What encoder interface does 1FK7042-2AC71-1GH2 use?
It has an absolute encoder with ENDAT- INTERFACE (ENCODER AM32S/R).
What protection and mechanical details are listed for 1FK7042-2AC71-1GH2?
It has a plain shaft, tolerance N, with holding brake, and degree of protection IP65 DE flange IP67.
What lifecycle status is listed for 1FK7042-2AC71-1GH2?
Product cancellation.