Technical Summary
| Product designation | SIMOTICS S Synchronous motor 1FK7 |
|---|---|
| Lifecycle | Product cancellation |
| Rated power PN | 0.94kW |
| Rated voltage UDC | 600V |
| Rated torque M0 | 3Nm (100K) |
| Rated speed NN | 6000rpm |
| Cooling | Naturally cooled |
| Frame size / mounting | FRAME SIZE IMB 5 (IM V1, IM V3) |
| Temperature sensor | WITH KTY TEMPERATURESENSOR |
| Power connector | POWER CONNECTOR ROTATABLE |
| Encoder | ABSOLUTE ENCODER 32 S/R SINGLETURN, 4096 ROTATION MULTITURN, WITH ENDAT- INTERFACE (ENCODER AM32S/R) |
| Degree of protection | IP65 |
Applications
Motor use in a SINAMICS S120 drive setup.
Use with an absolute encoder and ENDat- interface for feedback connection.
Key Features
SIMOTICS S Synchronous motor 1FK7 for exact order-number identification.
PN=0.94kW; UDC=600V; M0=3Nm (100K); NN=6000rpm.
Naturally cooled with FRAME SIZE IMB 5 (IM V1, IM V3).
Absolute encoder 32 S/R singleturn, 4096 rotation multiturn, with ENDat- interface (ENCODER AM32S/R).
Degree of protection IP65; Product cancellation.
Frequently Asked Questions
What is Siemens 1FK7042-2AK71-1GG1?
SIMOTICS S synchronous motor 1FK7.
What are the main electrical ratings of 1FK7042-2AK71-1GG1?
PN=0.94kW; UDC=600V; M0=3Nm (100K); NN=6000rpm.
Which encoder and interface are listed for 1FK7042-2AK71-1GG1?
Absolute encoder 32 S/R singleturn, 4096 rotation multiturn, with ENDat- interface (ENCODER AM32S/R).
What mounting and protection details are listed for 1FK7042-2AK71-1GG1?
Naturally cooled, FRAME SIZE IMB 5 (IM V1, IM V3), FLANGE 1, plain shaft, tolerance N, without holding brake, Degree of protection IP65.
What lifecycle status is supplied for 1FK7042-2AK71-1GG1?
Product cancellation.