Technical Summary
| Product designation | SIMOTICS S Synchronous motor 1FK7-HD |
|---|---|
| PN | 2kW |
| UDC | 600V |
| M0 | 6.4Nm (100K) |
| NN | 4500rpm |
| Cooling | Naturally cooled |
| Mounting | FRAME SIZE IMB 5 (IM V1, IM V3) FLANGE 1 |
| Temperature sensor | KTY temperature sensor |
| Power connector | rotatable |
| Encoder | absolute encoderr 2048 S/R + 4096 UMDREHUNGEN multiturn |
| Encoder interface | ENDAT-SCHNITTSTELLE (ENCODER AM2048S/R) |
| Shaft | shaft with fitted key, tolerance N |
| Holding brake | without holding brake |
| Degree of protection | IP65 |
| Lifecycle | Product cancellation |
Applications
Motor use in SINAMICS S120 drive systems.
Key Features
Exact product designation: SIMOTICS S Synchronous motor 1FK7-HD.
PN=2kW; UDC=600V; M0=6.4Nm (100K); NN=4500rpm.
Naturally cooled FRAME SIZE IMB 5 (IM V1, IM V3) FLANGE 1.
With KTY temperature sensor, power connector rotatable, and ENDAT-SCHNITTSTELLE (ENCODER AM2048S/R).
Degree of protection IP65; shaft with fitted key, tolerance N; without holding brake.
Product cancellation.
Frequently Asked Questions
What is Siemens 1FK7061-4CH71-1EA1?
It is a SIMOTICS S synchronous motor 1FK7-HD.
What are the key ratings of 1FK7061-4CH71-1EA1?
PN=2kW, UDC=600V, M0=6.4Nm (100K), and NN=4500rpm.
What encoder interface is on 1FK7061-4CH71-1EA1?
It has ENDAT-SCHNITTSTELLE (ENCODER AM2048S/R) with an absolute encoderr 2048 S/R + 4096 UMDREHUNGEN multiturn.
What mounting and protection details are listed for 1FK7061-4CH71-1EA1?
It is naturally cooled, FRAME SIZE IMB 5 (IM V1, IM V3) FLANGE 1, and has degree of protection IP65.
What lifecycle status is given for 1FK7061-4CH71-1EA1?
Product cancellation.