Technical Summary
| Product designation | SIMOTICS M compact asynchronous motor |
|---|---|
| Forced ventilation | forced ventilation |
| Air flow direction | DE–> NDE |
| Degree of protection | IP55 |
| Encoder | Incremental encoder SIN/COS 1 VPP 2048 S/R with C and D track (encoder IC2048S/R) |
| Temperature sensor | KTY 84-130 |
| Design | IM B3 (IM V5, IM V6) |
| Shaft | plain shaft WITHOUT FITTED KEY |
| Bearing | STANDARD |
| Vibration severity grade | R/A |
| Shaft and flange accuracy | R |
| Terminal box | R TERMINAL BOX (ABOVE) CABLE ENTRY ON THE RIGHT SIGNAL CONNECTION D-END |
| Lifecycle | Product cancellation |
| 1000 r/min | 12 kW 115 Nm 30 A 319 V |
| 1150 r/min | 13.5 kW 112 Nm 29 A 361 V |
| 1350 r/min | 15 kW 106 Nm 28 A 417 V |
| 1500 r/min | 16.6 kW 106 Nm 28 A 459 V |
Key Features
Exact Siemens order number 1PH8133-1MD00-0GA1 in the SIMOTICS M family.
Forced ventilation with direction of air flow DE–> NDE.
IP55 degree of protection.
Incremental encoder SIN/COS 1 VPP 2048 S/R with C and D track (encoder IC2048S/R).
With temperature sensor KTY 84-130.
Design IM B3 (IM V5, IM V6) with plain shaft WITHOUT FITTED KEY.
Frequently Asked Questions
What is Siemens 1PH8133-1MD00-0GA1?
It is a SIMOTICS M compact asynchronous motor.
What protection rating does 1PH8133-1MD00-0GA1 have?
It has IP55 degree of protection.
What encoder is included with 1PH8133-1MD00-0GA1?
It includes an incremental encoder SIN/COS 1 VPP 2048 S/R with C and D track (encoder IC2048S/R).
What mounting design does 1PH8133-1MD00-0GA1 use?
It is designed as IM B3 (IM V5, IM V6).
What lifecycle status is listed for 1PH8133-1MD00-0GA1?
Product cancellation.